مقدمة الشركة
منزل > بطاقة > Mv Cables

Mv Cables

العثور على {Keyword} بالجملة والاقتباسات من الصين. نحن الشركة المصنعة المحترفة لشركة {Keyword} ، المصنع والمصدرون متخصصون في {Keyword} مع جودة عالية.

نتاج

تصنيف:
طريقة العرض:
  • Rhz1-2ol 12/20kv Al Conductor Mv Cables 1X120 mm2 1X150 mm2 1X185 mm2

    Rhz1-2ol 12/20kv Al Conductor Mv Cables 1X120 mm2 1X150 mm2 1X185 mm2

    تصنيفها: كابل الجهد المتوسط
    المشاهدات: 256
    عدد:
    وقت الإصدار: 2025-07-16 07:47:43
    The RHZ1-2OL 12/20kV aluminum conductor MV cable is available in 1×120mm², 1×150mm² and 1×185mm² sizes, featuring high-quality aluminum conductor and special insulation design. With lightweight construction, excellent conductivity and weather resistance, it is suitable for 12/20kV medium voltage distribution systems, particularly ideal for overhead installation, substation connections and industrial zone power transmission in various environments.
  • NF C 33-226 Hta Cis 12/20kv 3X240mm Mv Cable

    NF C 33-226 Hta Cis 12/20kv 3X240mm Mv Cable

    تصنيفها: الأسلاك الخطية المعزولة العلوية
    المشاهدات: 302
    عدد:
    وقت الإصدار: 2025-08-06 03:20:04
    NF C 33 - 226 Hta Cis 12/20kV 3X240mm MV Cable Abstract​ 1. Introduction​ The NF C 33 - 226 Hta Cis 12/20kV 3X240mm MV Cable is a crucial component in modern medium - voltage power distribution systems. Designed in compliance with the NF C 33 - 226 standard, it is specifically engineered to transmit electrical power at 12kV to 20kV voltage levels. The 3X240mm configuration indicates three conductors, each with a cross - sectional area of 240 square millimeters, making it suitable for high - load applications.​ 2. Design and Structure​ 2.1 Conductors​ The conductors of this cable are typically made of high - purity aluminum or aluminum alloy. Aluminum is chosen for its excellent electrical conductivity, low weight, and cost - effectiveness. The 240mm² cross - sectional area allows for a high current - carrying capacity, ensuring efficient power transmission. The conductors are stranded, which enhances flexibility and reduces the risk of breakage during installation and operation.​ 2.2 Insulation​ High - quality cross - linked polyethylene (XLPE) is used as the insulation material. XLPE offers outstanding electrical insulation properties, high dielectric strength, and resistance to heat, moisture, and chemicals. It provides a reliable barrier between the conductors, preventing electrical leakage and short - circuits. The insulation thickness is carefully designed to meet the requirements of the 12/20kV voltage rating, ensuring safe and stable operation.​ 2.3 Outer Sheath​ An outer sheath, usually made of polyethylene (PE) or polyvinyl chloride (PVC), is added to protect the cable from mechanical damage, moisture ingress, and environmental factors. The outer sheath also provides additional insulation and flame - retardant properties, enhancing the overall safety of the cable.​ 3. Performance Parameters​ 3.1 Electrical Performance​ Voltage Rating: Rated for 12/20kV, it can withstand the electrical stress associated with medium - voltage power distribution.​ Current - Carrying Capacity: With a 240mm² conductor size, it has a high current - carrying capacity, typically around 400 - 500A depending on installation conditions. This allows it to power large industrial facilities, commercial complexes, and urban power grids.​ Resistance: The low - resistance conductors minimize power loss during transmission, improving the efficiency of the power system. The DC resistance of the 240mm² aluminum conductor is typically less than 0.1Ω/km at 20°C.​ Dielectric Strength: The XLPE insulation has a high dielectric strength, usually exceeding 30kV/mm, ensuring reliable insulation even under harsh electrical conditions.​ 3.2 Mechanical Performance​ Tensile Strength: The cable is designed to have a sufficient tensile strength to withstand the mechanical stress during installation and when suspended between poles. The stranded conductor construction and overall cable design contribute to its ability to resist stretching and breakage.​ Flexibility: Despite its large size, the stranded conductor design provides the cable with a certain degree of flexibility, making it easier to install around corners and through tight spaces.​ 3.3 Environmental Performance​ Temperature Range: It can operate in a wide temperature range, typically from - 40°C to + 90°C. The XLPE insulation remains stable and functional within this temperature range, ensuring reliable performance in various climates.​ Weather Resistance: The outer sheath and insulation materials are resistant to UV radiation, moisture, and ozone, making the cable suitable for outdoor installation in all weather conditions.​ Chemical Resistance: The cable is resistant to a wide range of chemicals, protecting it from corrosion and degradation in industrial environments where chemical exposure may occur.​ 4. Application Scenarios​ 4.1 Industrial Applications​ In industrial parks, factories, and manufacturing plants, the NF C 33 - 226 Hta Cis 12/20kV 3X240mm MV Cable is used to supply power to high - power machinery, motors, and equipment. Its high current - carrying capacity and reliable performance are essential for ensuring continuous and stable operation of industrial processes.​ 4.2 Urban Power Grids​ In urban areas, it plays a crucial role in distributing power from substations to residential and commercial areas. It can handle the high power demands of urban centers, providing a stable power supply to buildings, street lighting, and public facilities.​ 4.3 Renewable Energy Projects​ For wind farms and solar power plants, this cable is used to transmit the generated electricity from the power generation units to the grid. Its ability to withstand harsh environmental conditions and high - voltage transmission requirements makes it an ideal choice for renewable energy applications.​ 5. Installation and Maintenance​ 5.1 Installation​ Proper installation is essential for the cable's performance and lifespan. During installation, the cable should be carefully handled to avoid kinking, bending beyond its minimum bending radius (usually 15 - 20 times the cable diameter), and mechanical damage. The use of appropriate installation tools and techniques, such as cable pulling equipment and proper termination methods, is crucial. Terminations should be made using high - quality connectors and following the manufacturer's instructions to ensure good electrical contact and insulation.​ 5.2 Maintenance​ Regular maintenance is required to ensure the cable continues to operate safely and efficiently. Maintenance tasks include visual inspections for signs of damage, such as cuts, cracks, or swelling in the insulation or outer sheath. Electrical testing, such as insulation resistance testing and partial discharge testing, should be performed periodically to detect any potential problems. In case of any abnormalities, timely repairs or replacements should be carried out.​ 6. Conclusion​ The NF C 33 - 226 Hta Cis 12/20kV 3X240mm MV Cable is a high - performance medium - voltage cable that offers reliable power transmission in various applications. Its advanced design, excellent performance parameters, and wide range of application scenarios make it a preferred choice for power distribution projects. By following proper installation and maintenance procedures, its lifespan can be extended, ensuring long - term and stable power supply.
  • NF C 33-226 Hta Cis 12/20kv 3X240mm Mv Cable

    NF C 33-226 Hta Cis 12/20kv 3X240mm Mv Cable

    تصنيفها: الأسلاك الخطية المعزولة العلوية
    المشاهدات: 261
    عدد:
    وقت الإصدار: 2025-08-06 06:37:44
    NF C 33-226 Hta Cis 12/20kv 3X240mm Mv CableAbstract​ 1. Product Overview​ The NF C 33-226 Hta Cis 12/20kv 3X240mm Mv Cable is a high-performance medium-voltage power cable designed in compliance with the French standard NF C 33-226. The "12/20kV" rating indicates it operates at 12kV phase-to-ground and 20kV phase-to-phase, while "3X240mm" denotes three 240mm² conductors. The "Hta Cis" designation highlights its heat-resistant properties and suitability for industrial and infrastructure applications, making it a reliable choice for medium-voltage power transmission in demanding environments.​ 2. Structural Composition​ 2.1 Conductors​ The cable features three 240mm² conductors made of high-purity copper or aluminum, ensuring excellent electrical conductivity. Copper conductors offer 100% IACS conductivity, while aluminum options provide 61% IACS, both stranded to enhance flexibility for installation. The stranded design also improves tensile strength, allowing the cable to withstand mechanical stresses during deployment.​ 2.2 Insulation and Sheathing​ Each conductor is insulated with cross-linked polyethylene (XLPE), a material known for its high dielectric strength (>25kV/mm) and thermal resistance. This insulation layer, typically 2.0-2.5mm thick, is wrapped in a semiconducting layer to ensure uniform electric field distribution. The cable is further protected by a galvanized steel tape armor and a PVC or PE outer sheath, offering resistance to moisture, abrasion, and environmental contaminants.​ 3. Performance Characteristics​ 3.1 Electrical Performance​ Voltage and Current Handling: Rated for 12/20kV, with each 240mm² conductor carrying 400-450A continuously (30°C ambient), suitable for heavy-duty medium-voltage applications.​ Dielectric Strength: XLPE insulation withstands 45kV AC for 10 minutes in withstand tests, ensuring reliable operation under high-voltage conditions.​ Low Losses: Minimal conductor and dielectric losses, with AC resistance at 50Hz around 0.085Ω/km per conductor, optimizing energy efficiency.​ 3.2 Mechanical and Environiciency.​ 3.2 Mechanical and Environmental Performance​ Tensile Strength: Steel armor provides a breaking load of 15-20kN, enabling installation in underground or duct environments with spans up to 60 meters.​ Temperature Resistance: Operates reliably at -40°C to +90°C, with short-term overload capability up to 130°C, adapting to varying thermal conditions.​ Durability: Resistant to UV radiation, chemicals, and corrosion, ensuring a service life of 30+ years in industrial, urban, and underground settings.​ 4. Application Scenarios​ Industrial Facilities: Powering factories, refineries, and manufacturing plants with high power demands, where reliability and heat resistance are critical.​ Urban Distribution Networks: Connecting substations to commercial districts and high-rise buildings, withstanding urban environmental stresses.​ Infrastructure Projects: Supporting power transmission in airports, railways, and large-scale construction sites, compatible with underground and duct installations.​ Renewable Energy Plants: Transmitting power from solar farms and wind parks to the grid, enduring outdoor and remote conditions.​ 5. Conclusion​ The NF C 33-226 Hta Cis 12/20kv 3X240mm Mv Cable combines compliance with strict French standards, robust construction, and high performance. Its XLPE insulation, strong conductors, and protective sheathing make it an ideal solution for reliable medium-voltage power transmission in industrial, urban, and infrastructure applications.

أخبار

تصنيف:
لا توجد نتائج بحث!

حالة

تصنيف:
لا توجد نتائج بحث!

فيديو

تصنيف:
لا توجد نتائج بحث!

تحميل

تصنيف:
لا توجد نتائج بحث!

تجنيد

تصنيف:
لا توجد نتائج بحث!

المنتجات الموصى بها

لا توجد نتائج بحث!
تعرف على المزيد حول منتجات الكابلات
اتصل بـ Hongtai Cable Technology Co. ، Ltd
اتصل بنا

شركة Hongtai Cable Technology Co. ، Ltd

البريد الإلكتروني: export@qlcables.com

           sales@qlcables.com

Tel/Whatsapp:+86-18032066271

إضافة : منطقة التنمية الصناعية Xiaokou ، مقاطعة نينغجين ، مدينة Xingtai , مقاطعة Hebei ، الصين

حقوق الطبع والنشر © Hongtai Cable Technology Co. ، Ltd  الدعم الفني:Ronglida Technology


خريطة الموقع

يستخدم هذا الموقع ملفات تعريف الارتباط لضمان حصولك على أفضل تجربة على موقعنا.

يقبل يرفض